NULITE BLN-050TC3 R290 High-Temperature Heat Pump, 50 kW

SKU: NULITE-BLN-050TC3-R290 Product Type: Equipment ● On Request

Commercial R290 inverter heat pump NULITE BLN-050TC3: up to 50 kW heating, water up to 75 °C, operation at −25 °C, and cascade control for 16 units.

NULITE BLN-050TC3 R290 High-Temperature Heat Pump, 50 kW (SKU NULITE-BLN-050TC3-R290) is available to order from GeoWatt. Supply: Kazakhstan, Kyrgyzstan, Uzbekistan and Central Asia.

Models: BLN-050TC3
Type: High-temperature air-to-water monobloc heat pump
Operating modes: Heating; cooling; DHW; heating plus DHW; cooling plus DHW
Heating capacity: 17.56–50 kW
Input power: 2.61–12.88 kW
Operating current: 5.46–18.8 A

NULITE BLN-050TC3 is a commercial high-temperature air-to-water heat pump with inverter control and natural R290 refrigerant. A single monobloc unit delivers up to 50 kW of heating, up to 35 kW of cooling, and outlet water up to 75 °C. It is intended for year-round heating, cooling, and domestic hot-water systems.

NULITE BLN-050TC3 heat-pump refrigerant circuit
Inverter refrigerant-circuit arrangement inside the cabinet

Five operating modes

The controller supports heating, cooling, domestic hot water, heating plus DHW, and cooling plus DHW. This allows one equipment type to serve several seasonal duties and reduces the number of separate plant items in the building services system.

Capacity and operating envelope

At A7/6 °C and W30/35 °C, the heating capacity modulates from 17.56 to 50 kW. At the higher W47/55 °C water condition, the unit delivers 17.95–49 kW. Cooling capacity at A35/24 °C and W12/7 °C is 10–35 kW. The manufacturer's heating envelope covers −25 to +45 °C ambient: maximum outlet water temperature is 65 °C at −25 °C, 67 °C at −20 °C, 69 °C at −15 °C, and reaches 75 °C from −10 °C upward.

NULITE BLN-050TC3 R290 heating operating envelope
Heating operating envelope stated in the brochure

Inverter architecture and cascade control

The DC-inverter rotary compressor and inverter fan modulate output to match the current load. Weather-compensation curves, forced defrosting, and a sterilization function help adapt operation to the site. Cascade control for up to 16 units is stated for larger systems, supporting staged capacity, redundancy, and future expansion.

Local and remote control

The local interface is a 5-inch touchscreen with support for up to 20 languages. The brochure lists Wi-Fi, RS-485, a mobile app, and an IoT web platform for remote status viewing, setpoint adjustment, and equipment notifications. Remote features and licensing scope should be confirmed at order stage.

NULITE BLN-050TC3 app and web monitoring platform
Example of remote monitoring through the app and web interface

Applications

  • hotels, resorts, dormitories, and serviced-apartment developments;
  • hospitals, clinics, sports centers, pools, and shower facilities;
  • schools, campuses, administrative buildings, and public facilities;
  • restaurants, canteens, laundries, and food-processing sites;
  • warehouses, workshops, manufacturing, and logistics facilities;
  • central heating, cooling, and DHW for residential and commercial developments;
  • processes requiring water temperatures up to 75 °C.

Hydraulic connection and design

Rated water flow is 8.6 m³/h, with a DN40, G 1-1/2″ connection and a maximum water-side pressure drop of 65 kPa. The unit requires a 380–415 V, three-phase, 50 Hz supply. The typical arrangement includes a primary heat-pump circuit, circulation pumps, buffer storage, heating and cooling circuits, isolation valves, and safety devices.

NULITE BLN-050TC3 cascade connection diagram
Conceptual cascade arrangement with buffer storage

Selection is based on design load, DHW consumption profile, water-temperature requirements, climate, acoustic limits, and available electrical capacity. The system design must address buffer volume, hydraulic separation, water quality, freeze protection, condensate drainage, unrestricted airflow, service clearances, and requirements for R290 equipment. R290 is a flammable refrigerant, so charge limits, ventilation, separation distances, and safety measures must be determined by the project and applicable regulations.

Specifications were transcribed from the supplied brochure. Actual capacity and COP depend on air and water temperatures, flow rate, and operating mode. Configuration, certification, IoT availability, and the final system arrangement must be confirmed before ordering.

Similar Products

NULITE Unpressurized Water Tanks 80–2000 L
On Request
NULITE

NULITE Unpressurized Water Tanks 80–2000 L

SKU: NULITE-WT-UNPRESSURE-80-2000L

NULITE unpressurized cylindrical and sectional water tanks for water storage and heat-pump projects,...

NULITE Pressurized Water Tanks 80–2000 L
On Request
NULITE

NULITE Pressurized Water Tanks 80–2000 L

SKU: NULITE-WT-PRESSURE-80-2000L

NULITE pressurized storage tanks from 80 to 2000 L for DHW, heat-pump, and solar systems, with 50 mm...

NULITE FP-WA Concealed Ceiling Fan Coil Units 1.8–12.6 kW
On Request
NULITE

NULITE FP-WA Concealed Ceiling Fan Coil Units 1.8–12.6 kW

SKU: NULITE-FCU-CONCEALED-FP-WA

NULITE FP-WA concealed ceiling fan coils: 9 models with 1.8–12.6 kW cooling, up to 18.9 kW heating, ...

NULITE FP-LM Floor Standing Fan Coil Units 1.8–12.6 kW
On Request
NULITE

NULITE FP-LM Floor Standing Fan Coil Units 1.8–12.6 kW

SKU: NULITE-FCU-FLOOR-FP-LM

NULITE FP-LM floor-standing fan coils: 9 heating and cooling models with 1.8–12.6 kW cooling and up ...